| Input Parameters | Input Voltage Range | 350-460V (Three phase) |
| Input Frequency Range | 45 – 65 Hz |
| Maximum Input Current | 16A rms per phase |
| Input Voltage Range | Three Phase, 5 Wire (R, Y, B, N, PE) |
| Power Output | Output Voltage Range | 350-460V (Three phase) |
| Output Current | 16A rms per phase |
| Connector Type | Type-2 AC |
| No. of output | 1 |
| Mode of charging | Mode – 3 |
| Protection & Safety | Safety Parameters | Input Over Voltage , Input Under Voltage , Over Current, Short Circuit, Surge Protection, Over Temperature, Residual Current Protection, Emergency Shut-down with alarm |
| Interface and Control
Functions |
| Visual Indication | Presence of Input Supply, Error Indicator via LED glow sign |
| Emergency Stop | Push Button |
| User Authentication | Mobile Application,
QR Code,RFID Card |
| Communication | Between EVSE and Central Server | OCPP 1.6J/OCPP 2.0.1 |
| Between EVSE and EV | Low Level Communication as per IEC 61851-1 |
| Interface | Wifi, Bluetooth (for configuration and settings), GSM
(2G/3G/4G) |
| Mechanical | Ingress Protection | IP65 |
| Cooling | Natural Air Cooling |
| Operating Temperature | -25 C to 55 C |
| Storage Temperature | -25 C to 70 C |
| Altitude | 2000 m |
| Humidity (Non-condensing) | 5% to 95% |
| Material | Mild Steel with phosphated powder coating |
| Impact Resistance | IK10 |
| Weight | 5.5 Kg |
| Dimensions (HxWxD) in mm | 280x235x100 |
| Mounting | Wall/ pedestal mounted |